Analisis Pengulangan (REPEAT) Foto Panoramik di Instalasi Radiologi RSPAU Dr. Suhardi Hardjolukito

Authors

  • Azizah Azizah Universitas ‘Aisyiyah Yogyakarta
  • Anisa Nur Istiqomah Universitas ‘Aisyiyah Yogyakarta
  • Sofie Nornalita Dewi Universitas ‘Aisyiyah Yogyakarta

DOI:

https://doi.org/10.55606/nusantara.v5i3.6500

Keywords:

Machine Error, Panoramic Radiography, Patient Safety, Quality Control, Repeats

Abstract

Panoramic radiography is an imaging technique that plays a crucial role in dental practice, particularly in supporting the diagnosis and treatment planning process. Image quality that does not meet diagnostic standards can lead to the need for repeat imaging. The high rate of repeat panoramic imaging at the Radiology Unit of Dr. Suhardi Hardjolukito Air Force Base Hospital (RSPAU) is an indicator of the need for further study of the causal factors. The purpose of this study was to identify the causes of repeat panoramic radiography examinations, calculate the percentage contribution of each factor, assess radiographers' understanding of optimal image quality criteria, and explore appropriate strategies to reduce the frequency of repeat examinations. This study used a mixed methods approach with quantitative and qualitative descriptive approaches. Data were collected through observation, interviews, questionnaires, and documentation during August–October 2024 at the Radiology Unit of Dr. Suhardi Hardjolukito Air Force Base Hospital. The sample included 15 radiographers for the questionnaire and 3 radiographers for the interviews. An analysis of 916 panoramic radiography examinations revealed 57 repeat cases, with a rate of 6.2%. The primary factors causing repeats were machine error (57.8%), followed by positioning errors (24.5%), artifacts (10.5%), human error (5.3%), and patient movement (1.8%). Radiographers' understanding of the criteria for good panoramic images was high, with 66.7% answering all questions correctly. The primary effort implemented to reduce repeat rates is the implementation of routine quality control of equipment. The high repeat rate, exceeding national tolerance limits, indicates the need for technical and procedural improvements. Routine quality control and material refresher courses are needed to reduce repeat rates and improve patient safety.

 

Downloads

Download data is not yet available.

References

Arifin, N. F., Mattalitti, S. O. F., & Jaya, T. (2023). Hubungan tingkat pengetahuan teori dan kemampuan interpretasi gambar radiografi panoramik kedokteran gigi pada mahasiswa kepaniteraan klinik. DENThalib Journal, 1(2), 28–32.

Artitin, C. (2022). Analisa pengulangan (repeat) radiograf di unit radiologi Rumah Sakit Umum Daerah Mohammad Natsir Solok. Jurnal Teras Kesehatan, 5(1), 25–30. https://doi.org/10.38215/jtkes.v5i1.72

Biloro, A. R. (2024). Studi kasus reject dan repeat film radiografi di Instalasi Radiologi RS PKU Muhammadiyah Delanggu. Jurnal Dinamika Kesehatan Terpadu, 5(4), 47–54. https://ijurnal.com/1/index.php/jdkt

Fatimah, D. L. (2019). Analisis faktor penyebab repeat exposure citra digital dengan menggunakan computed radiography (CR). Jurnal Radiografer Indonesia, 2(2), 106–110. https://doi.org/10.55451/jri.v2i2.43

Izzetti, R., Nisi, M., Aringhieri, G., Crocetti, L., Graziani, F., & Nardi, C. (2021). Basic knowledge and new advances in panoramic radiography imaging techniques: A narrative review on what dentists and radiologists should know. Applied Sciences (Switzerland), 11(17), Article 7858. https://doi.org/10.3390/app11177858

Lalopa, N., Mufida, W., & Saputri, L. D. (2024). Analisis pengulangan foto pada pemeriksaan panoramik di Instalasi Radiologi RSUD Dr. Soeroto Ngawi. Prosiding Seminar Nasional Penelitian dan Pengabdian Kepada Masyarakat LPPM Universitas 'Aisyiyah Yogyakarta, 2(September), 1755–1762. https://proceeding.unisayogya.ac.id/index.php/prosemnaslppm/article/view/303

Lampignano, J. P. (2018). Bontrager's textbook of radiographic positioning and related anatomy (L. E. Kendrick & J. P. Lampignano, Eds.; 9th ed.). Elsevier.

Nabihah, K. K., & Lubis, M. N. P. (2023). The correlation of the change in vertical angulation of the beam in the bisecting technique to the length of the tooth. Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI), 7(1), 15. https://doi.org/10.32793/jrdi.v7i1.978

Nafiiyah, N., Astuti, E. R., Putra, R. H., & Asymal, A. (2025). System identification position error in panoramic radiography: A review. Jurnal Ilmiah Teknik Elektro Komputer dan Informatika (JITEKI), 11(1), 68–78. https://doi.org/10.26555/jiteki.v11i1.30598

Ozdil, N., Oflezer, O., Gokkaya, B., Bahadir, H., & Orhan, K. (2022). Improper patient positioning incidence for panoramic radiographic imaging of pediatric patients: Retrospective study. Balkan Journal of Dental Medicine, 26(2), 88–92. https://doi.org/10.5937/bjdm2202088O

Prativi, S. A. (2021). Perbedaan pengetahuan struktur anatomi normal radiograf panoramik antara mahasiswa preklinik dan klinik. B-Dent: Jurnal Kedokteran Gigi Universitas Baiturrahmah, 1(1), 73–80. https://doi.org/10.33854/jbd.v1i1.492

Ramadhan, A. Z., Sitam, S., Azhari, A., & Epsilawati, L. (2020). Gambaran kualitas dan mutu radiograf. Jurnal Radiologi Dentomaksilofasial Indonesia (JRDI), 3(3), 43. https://doi.org/10.32793/jrdi.v3i3.445

Reski, M. A., & Sugianto, I. (2022). Identifikasi kesalahan radiografi periapikal digital teknik bisecting: Literature review. Sinnun Maxillofacial Journal, 4(2), 104–112. https://doi.org/10.33096/smj.v4i02.91

Sabilonnaja, M. P., Ade, I., Liscyaningsih, N., & Utami, A. P. (2024). Analisis pengulangan citra digital dengan menggunakan digital radiography di Instalasi Radiologi RSUD dr. R. Soetijono Blora. Prosiding Seminar Nasional Penelitian dan Pengabdian Kepada Masyarakat LPPM Universitas 'Aisyiyah Yogyakarta, 2(September), 2130–2135.

Suparno, N. R., Faizah, A., & Nafisah, A. N. (2023). Assessment of panoramic radiograph errors: An evaluation of patient preparation and positioning quality at Soelastri Dental and Oral Hospital. The Open Dentistry Journal, 17(1), 1–9. https://doi.org/10.2174/0118742106261974230925073155

Whitley, S., Jefferson, G., Holmes, K., Sloane, C., Anderson, C., & Hoadley, G. (2015). Clark's positioning in radiography. https://doi.org/10.1201/b13534

Widiatmoko, M. E., & Sari, N. A. P. (2025). Analysis of factors causing repetition of computed radiography images in an effort to improve the quality of health services in radiology. Kontribusia: Research Dissemination for Community Development, 8(1), 46. https://doi.org/10.30587/kontribusia.v8i1.8795

Yusuf, M., Novianti, S. I., Bakar, A., & Noor, V. A. (2023). Mutu radiograf panoramik digital ditinjau dari segi artefak pada rumah sakit di Kota Semarang, Indonesia. E-GiGi, 11(2), 189–195. https://doi.org/10.35790/eg.v11i2.44935

Downloads

Published

2025-08-06

How to Cite

Azizah Azizah, Anisa Nur Istiqomah, & Sofie Nornalita Dewi. (2025). Analisis Pengulangan (REPEAT) Foto Panoramik di Instalasi Radiologi RSPAU Dr. Suhardi Hardjolukito. Nusantara: Jurnal Pengabdian Kepada Masyarakat, 5(3), 502–514. https://doi.org/10.55606/nusantara.v5i3.6500

Similar Articles

<< < 2 3 4 5 6 7 8 9 > >> 

You may also start an advanced similarity search for this article.