SISTEM MANAJEMEN PROTEKSI MOTOR RELAY GE MULTILINE 269 PLUS PADA MOTOR FORCED DRAFT FAN DI PT. INDONESIA POWER PGU SURALAYA

Authors

  • Mastiri Mastiri Universitas Sultan Ageng Tirtayasa
  • Desmira Desmira Universitas Sultan Ageng Tirtayasa

DOI:

https://doi.org/10.55606/jurritek.v1i2.278

Keywords:

Fan, Protection, unbalance.

Abstract

Electrical energy continues to grow over time, power plants with large capacities are the main sources of electricity in Indonesia, one of which is the Steam Power Plant (PLTU). In the field of power plants that use coal always need air during the electricity production process. This study aims 1) to determine the protection management system on the Forced Draft fan motor using GE Multilin 269 Plus, 2) Setting GE Multilin 269 Plus as protection, 3) The results of the protection in the form of Normal Motor, Alarm, and Trip conditions in the accumulation of imbalance (Unbalance) ). The method used is a quantitative research method based on analysis, taking data and then analyzing the data obtained. The results of this quantitative study regarding the Unbalance value or imbalance of the electric motor analyzed resulted in a value of 5.8% for normal conditions, 10.86% for alarm conditions on multilin and 15.50% in trip conditions or the motor had stopped. These values ​​are obtained from the results of calculations comparing negative sequence currents and positive sequence currents (In/Ip). The conclusion obtained is that the GE Multilin 269 Plus protects the electric motor from system damage by using a current sensor and through a setting point that is adjusted to the provisions of NEMA (National Electrical Manufacturers Association) with an unbalance value of more than 15% for trips, more than 10% for alarm conditions and less than 10% under normal conditions

References

Abidin, Z., Priangkoso, T., & Darmanto, D. (2013). Pengujian Performance Motor Listrik Ac 3 Fasa Dengan Daya 3 Hp Menggunakan Pembebanan Generator Listrik. Jurnal Ilmiah MOMENTUM, 9(1).

Almanda, D., & Alamsyah, A. N. (2017). Sistem Pengendalian Motor Sinkron Satu Fasa Berbasis Mikrokontroler. eLEKTUM, 13(2), 1-6.

SYUKUR, A., & SULTAN, A. (2021). STUDI SISTEM PROTEKSI MOTOR INDUKSI. Universitas Muhammadiah Makasar.

Iradiratu, D. P. K., Dewantara, B. Y., & Janudin, A. M. (2019). Deteksi Kerusakan Inner Race Bearing Menggunakan Motor Current Signature Analysis Berbasis Fast Fourier Transform. Jurnal Teknik Elektro dan Komputer TRIAC, 6(1), 14-17.

Maulidhasari, D. N., Yuantari, M. C., & Nurjanah, N. (2011). Faktor-Faktor Yang Berhubungan dengan Perilaku Berbahaya (Unsafe Action) Pada Bagian Unit Intake PT. Indonesia Power Unit Bisnis Pembangkitan (UBP) Semarang 2011. VISIKES: Jurnal Kesehatan Masyarakat, 10(1).

Multilin, G. E. (2008). 469 Motor Mangement Relay Intruction Manual.

Ramadhani, & Wardoyo.S. (2014). Analisa Setting Point Sistem Proteksi Motor Induksi 3 fasa 10,5 kV Unit 5-7 PLTU Suralaya Terhadap Gangguan Unbalance. Cilegon: Jurusan Teknik Elektro, Universitas Sultan Ageng Tirtayasa

Priambodo, R. B., & Indartono, I. (2015). ANALISA EFISIENSI FORCED DRAFT FAN B UNIT# 10 PT. PJB UBJ O & M PLTU REMBANG (EFFICIENCY ANALYSIS OF FORCED DRAFT FAN B UNIT# 10 PT. PJB UBJ O & M REMBANG) (Doctoral dissertation, D3 Kerjasama PT. PLN Bidang Mesin Fakultas Teknik).

Yunitasari, A. V., & Pramono, S. (2021). SISTEM PROTEKSI OVER CURRENT RELAY MOTOR FORCED DRAFT FAN PADA PEMBANGKIT LISTRIK TENAGA UAP. Jurnal Teknologi, 13(1), 55-62.

Downloads

Published

2022-09-29

How to Cite

Mastiri Mastiri, & Desmira Desmira. (2022). SISTEM MANAJEMEN PROTEKSI MOTOR RELAY GE MULTILINE 269 PLUS PADA MOTOR FORCED DRAFT FAN DI PT. INDONESIA POWER PGU SURALAYA. JURAL RISET RUMPUN ILMU TEKNIK, 1(2), 40–51. https://doi.org/10.55606/jurritek.v1i2.278