Analisis Pemeriksaan CT Scan Leher Dengan Kontras Pada Kasus Tumor Tiroid Di Instalasi Radiologi RSUD Provinsi NTB

Authors

  • Rahmah Rahmah Akademi Teknik Radiodianostik dan Radioterapi Bali
  • Kadek Yuda Astina Akademi Teknik Radiodianostik dan Radioterapi Bali
  • I Bagus Gede Dharmawan Akademi Teknik Radiodianostik dan Radioterapi Bali

DOI:

https://doi.org/10.55606/innovation.v1i4.1910

Keywords:

CT Scan Of The Neck, Contrast Media Volume, Contrast Media Injection

Abstract

Background: Thyroid tumors are abnormal growths of the thyroid gland, which can be benign or malignant tumors such as papillary, follicular, medullary or anaplastic types (Aldino, 2018). CT scan of the neck according to (Lee at al, 2016) The contrast media used consists of 80 ml of non-ionic contrast media followed by 20 ml of saline given through the antecubital vein using a power injector and a 20 gauge intravenous catheter at a speed of 2.5- 3.0 ml/sec. According to (Yang et al., 2016) 80-100 ml of 300 mg/L omnipaque contrast media is injected through the cubital vein at a rate of 2.7-3.0 mL/s. And according to (Deng et al., 2019), 80 ml of iopromide (300 mgl/mL) contrast media is injected intravenously at a rate of 3 ml/sec. The aim of this research is to determine the procedure for a CT scan of the neck with contrast in cases of thyroid tumors in the radiology installation at the NTB Provincial Regional Hospital. Method: The type of research carried out is qualitative research with a case study approach. Data were collected by observation, interviews with one radiologist and three radiographers and documentation. Data collection was carried out from June to July 2023. Data analysis was carried out using an interactive model system. Results: This study shows that the contrast media used in CT scans of the neck uses 50 ml contrast media on the grounds that 50 ml contrast media can confirm the diagnosis because in the case of tumors in the thyroid you only want to see whether there is enhancement of the tumor. And the contrast media injection is carried out manually by a radiology nurse on the grounds that it is sufficient to confirm the diagnosis if it is carried out with proper control so that the examination is simpler and the processing time is faster. Conclusion: There is a difference in the CT scan of the neck between theory and the NTB provincial hospital where in theory Lee et al (2016) explains that 80 ml of contrast media is used and an injector is used at a speed of 2.5-3.0 ml/s while the provincial hospital NTB uses 50 ml contrast media and is injected manually by a radiology nurse on the grounds that this can confirm the diagnosis.

References

Adham M, Aldino N. Diagnosis Dan Tatalaksana Karsinoma Tiroid Berdiferensiasi. J Fak Kedokteran, Univ Indones. 2018;48(2):197.

Ariyansyah MR. Karakteristik Penderita Kanker Tiroid di Rsup DR Kariadi Semarang Periode Januari 2020 - Desember 2021. J Fak Kedokteran, Univ Diponegoro. 2022;

Bontrager KL, P lampignanano J. Bontrager‘s Handbook of Radiographic Positioning and Techniques. Journal of Chemical Information and Modeling; 2014.

Rofita, Satoto B, Handoko BD. Pemanfaatan Saline Pada Pemeriksaan MSCT Leher Dengan Kontras. 2020;

Lee young hen, seo, hyung Suk S, Al. Feasibility Study of a Contrast-Enhanced Multi-Detector CT ( 64 Channels ) Protocol for Papillary Thyroid Carcinoma : Korea Univ Coll Med [Internet]. 2016;26(5):13–5. Available from: https://doi.org/10.1089/thy.2015.0415

Yang T, Huang Y, Jing X, Gai X, Li W. CT-detected solitary thyroid calcification : an important imaging feature for papillary carcinoma. Onco Targets Ther [Internet]. 2016;6273–9. Available from: https://doi.org/10.2147/OTT.S113369

Deng D, Chen X, Wang H, Wu H. Typical manifestations of Hürthle cell adenoma of the thyroid on contrast-enhanced CT. Medicine (Baltimore) [Internet]. 2019;22(April). Available from: https://doi.org/10.1097/MD.0000000000015866

Seeram. COMPUTED TOMOGRAPHY. American Speech; 2016.

Hadianto, septian wahyu martini L. Asuhan Keperawatan Pada Pasien Kanker Tiroid Dalam Pemenuhan Kebutuhan Aman dan Nyaman. Fak Ilmu Kesehat Univ Kusuma Husada Surakarta. 2020;2–12.

Parura, yolanda Kandou PRD, Pontoh V. Pola kanker tiroid periode Juli 2013 – Juni 2016 di RSUP Prof. Dr. R. D Kandou Manado. J e-Clinic. 2016;4.

Ar-rahmah, Arsyka Hunjri A, Wahyuni I, Journal H, Dokter P, Kedokteran F, Lampung U. MANAJEMEN ANESTESI UMUM TIROIDEKTOMI TOTAL PADA TUMOR TIROID BILATERAL DENGAN SUSPEK KEGANASAN : Indones Trust Heal J. 2022;5(1):6–11.

Devi HL, Safarini B, Sulaksono N. Peranan teknik split-bolus terhadap kualitas citra pada pemeriksaan msct leher. 2018;1–8.

Flohr T, Ohnesorge B. Multi-slice CT Technology. Multi-Slice Dual-Source CT Card Imaging Princ - Protoc - Indic - Outlook, d, 41–69. 2007;41–6.

Bae KT. Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches. Radiology [Internet]. 2010;256(1). Available from: https://doi.org/10.1148/radiol.10090908

Wijokongko Sigit, Ardiyanto Jeffri F. Protokol Radiologi CT Scan dan MRI. Magelang: Inti medika Pustaka; 2016.

Smith-bindman R. Use of Advanced Imaging Tests and the Not-So-Incidental Harms of Incidental Findings. JAMA Intern Med. 2017;177(8):1176–80.

Hoang JK, Langer JE, Middleton WD. Managing Incidental Thyroid Nodules Detected on Imaging : White Paper of the ACR Incidental Thyroid Findings Committee. J Am Coll Radiol [Internet]. 2014;12(2):143–50. Available from: http://dx.doi.org/10.1016/j.jacr.2014.09.038

Durand, M. L. et al. ACR Appropriateness Criteria â Acute Respiratory Illness in Immunocompetent Patients. J Am Coll Radiol [Internet]. 2018;15(11):S240–51. Available from: https://doi.org/10.1016/j.jacr.2018.09.012

Tessler FN, Middleton WD, Grant EG, Hoang JK, Berland LL, Teefey SA, et al. HEALTH SERVICES RESEARCH AND POLICY ACR Thyroid Imaging , Reporting and Data System ( TI-RADS ): White Paper of the ACR TI-RADS Committee. J Am Coll Radiol [Internet]. 2017;14(5):587–95. Available from: http://dx.doi.org/10.1016/j.jacr.2017.01.046

Perni, S. et al. Tumor Location within the Thyroid is an Important Prognostic Factor. Surgical Oncology; 2020. p. 33, 53–8.

Herts, B. R., & Silverman SG. Individualized strategies for contrast administration in CT. American Journal of Roentgenology; 2018. p. 268–75.

Smith, A. et al. The Economic Impact of Reducing Contrast Volume in CT Scan. Journal of Radiological Economics; 2017. p. 110–6.

Zhang, Y. et al. Manual vs. Automatic Injection of Contrast Medium in CT: A Comparative Study. Radiology Today; 2018. p. 204–10.

Johnson, P. et al. Benefits of Automatic Injector Systems in CT Imaging: A Review. Clinical Radiology; 2016. p. 15–21.

Park, J. H., Lee, K. H., & Kim SY. Optimized contrast volume for CT scan in thyroid assessment. Journal of Clinical Imaging; 2018. p. 21–6.

Brown, K. et al. Re-evaluating Medical Practices for the 21st Century. Medicine Today; 2020. p. 532–9.

Downloads

Published

2023-09-21

How to Cite

Rahmah Rahmah, Kadek Yuda Astina, & I Bagus Gede Dharmawan. (2023). Analisis Pemeriksaan CT Scan Leher Dengan Kontras Pada Kasus Tumor Tiroid Di Instalasi Radiologi RSUD Provinsi NTB. Journal of Educational Innovation and Public Health, 1(4), 252–264. https://doi.org/10.55606/innovation.v1i4.1910